Safety recalls: residential HVAC since 2010

Every CPSC recall of residential heat pumps, air handlers, coils, packaged units and furnaces — models, hazard and remedy, in CPSC’s own words.

Checked against the sources below on October 7, 2026

The short answer

Since 2010 the Consumer Product Safety Commission has announced 18 recalls of residential heating and cooling equipment of the kinds a heat pump tech works on. Each one covers specific models and serial ranges — check the unit in front of you against the CPSC notice, not against the brand.

How to read this list

A recall says that particular units have a defect and what the manufacturer will do about it. It says nothing about the rest of that manufacturer’s products. Several of the recalls below are a wrong label or a missing ground, not a failing component. Three of them are one drain-pan recall and its two expansions.

2025

CPSC 25369Packaged unit

Trane Recalls Gas/Electric Packaged Units Due to Risk of Gas Leak, Fire Hazard

Hazard
The fuel gas valve can open unexpectedly, allowing a gas leak and posing a fire hazard.
Remedy
Consumers should immediately stop using the heating mode of the recalled units and contact their dealer who installed the unit to schedule an appointment for a free inspection and repair, by replacing the ignition board of the unit. Consumers with Trane products can locate their nearest dealer at www.trane.com/residential/en/dealer-locator/. Consumers with American Standard products can locate their nearest dealer at www.americanstandardair.com/find-your-dealer/. Consumers can also contact Trane or American Standard directly for support.
Units
About 4,790
Models, serial ranges and contact at CPSC →

2024

CPSC 24286Heat pump

Daikin Comfort Technologies Manufacturing Recalls Daikin FIT, Amana Brand S-series, and Goodman SD Heat Pumps Due to Risk of Excessive Heat Exposure

Hazard
A power interruption in the heat pump can result in the product providing heat when the power resumes, despite the thermostat being in cooling mode, posing a risk of excessive heat exposure to consumers.
Remedy
Daikin Comfort Technologies (DCT) is updating the software remotely for consumers whose Daikin FIT, Amana Brand S-series, and Goodman SD heating and cooling systems are connected to WiFi. Consumers with systems not connected to WiFi should register for the recall at http://www.goodmanmfg.com/fit-recall to receive instructions to perform the update.
Units
About 56,000 (In addition, about 5,522 were sold in Canada)
Models, serial ranges and contact at CPSC →
CPSC 24260Packaged unit

Daikin Comfort Technologies Manufacturing Recalls Amana, Daikin, Goodman-Branded Air Conditioning and Heat Pump Packaged Units Due to Fire Hazard

Hazard
The unit's serial plate can have incorrect electrical ratings which can lead to incorrect wirings being used, posing a fire hazard.
Remedy
Consumers should not attempt to open the outside electrical panel of the recalled air conditioning and heat pump units, and immediately contact Daikin Comfort Technologies Manufacturing L.P. (DCT) for a free repair and inspection. DCT is contacting all known purchasers directly.
Units
About 12,100
Models, serial ranges and contact at CPSC →
CPSC 24080Indoor coil

Daikin Comfort Technologies Manufacturing (formerly Goodman Manufacturing Company L.P.) Expands Recall of Evaporator Coil Drain Pans to Include Additional Units

Hazard
The molded plastic drain pan located at the bottom of the evaporator coil can overheat, melt and deform, posing a fire hazard.
Remedy
Consumers should contact Daikin Comfort Technologies Manufacturing L.P. (DCT) to determine whether your unit is included in this recall and to register for the free repair by a qualified technician. DCT is contacting all registered consumers where records indicate their gas furnace system is subject to the recall.
Units
About 3,600 additional units (In addition, about 12 were sold in Canada) (298,300 evaporator coil drain pans, and 44,000 in Canada, were previously recalled in November 2021 and in July 2022)
Models, serial ranges and contact at CPSC →

2023

CPSC 23218Gas furnace

Allied Air Enterprises Recalls Armstrong Air and Air Ease Gas Furnaces Due to Carbon Monoxide Poisoning Hazard

Hazard
A component inside the furnace was improperly assembled, causing the furnace to produce high levels of carbon monoxide (CO) under certain operating conditions, which poses a risk of CO poisoning to the consumer.
Remedy
Contact Allied Air Enterprises to schedule a free in-home repair by an authorized technician who will replace the incorrect component. Allied Air Enterprises is contacting all known distributors directly, who will work with dealers to contact all known consumers who purchased the recalled units. Consumers who continue to use the recalled furnaces while awaiting repair should have working carbon monoxide alarms on every level of the home and outside sleeping areas.
Units
About 9,255
Models, serial ranges and contact at CPSC →

2022

CPSC 22193Indoor coil

Daikin Comfort Technologies Manufacturing (formerly Goodman Manufacturing Company, L.P.) Expands Recall of Evaporator Coil Drain Pans to Include Those Installed with Non-Condensing Gas Furnaces Due to Fire Hazard

Hazard
The molded plastic drain pan located at the bottom of the evaporator coil can overheat, melt and deform, posing a fire hazard.
Remedy
Consumers should contact Daikin Comfort Technologies Manufacturing, L.P. (DCT) to determine whether your unit is included in this recall and to register for the free repair by a qualified technician. DCT is contacting all registered consumers where records indicate their gas furnace system is subject to the expanded recall.
Units
About 298,300 (In addition, about 44,000 were sold in Canada)
Models, serial ranges and contact at CPSC →

2021

CPSC 22021Indoor coil

Goodman Manufacturing Company Recalls Evaporator Coil Drain Pans Installed with Condensing Gas Furnaces Due to Fire Hazard

Hazard
The molded plastic drain pan located at the bottom of the evaporator coil, when installed with a residential condensing gas furnace in an up-flow configuration, can overheat, melt, and deform, posing a fire hazard.
Remedy
Contact Goodman Manufacturing Company to register for the free repair. Visit Goodman's recall website to use a model verification tool for evaporator coil, furnace, and outdoor condenser. The tool provides step-by-step instructions to determine if your gas furnace system is subject to this recall. Goodman will also assist consumers in gathering information on their units including the drain pan serial number, the furnace model number and brand name, and the model number for the outdoor system.
Units
About 298,300 (In addition, about 44,000 in Canada)
Models, serial ranges and contact at CPSC →

2020

CPSC 20083Ductless heat pump

Lennox Industries Recalls Ductless Heat Pumps Due to Fire Hazard

Hazard
Internal electrical components can fail, allowing the units to overheat, posing a fire hazard.
Remedy
Consumers should immediately contact their installing servicer, dealer, or contractor to arrange for a free replacement of the outdoor unit. While awaiting replacement, consumers should monitor the recalled heat pumps while they are being operated and keep foliage and other flammable items at least 24 inches away from the recalled units. Lennox is contacting all known independent dealers about the recall directly. The dealers will contact individual consumers to arrange for recalled outdoor units to be removed and replacement units to be installed.
Units
About 1,650 (in addition, about 380 were sold in Canada)
Models, serial ranges and contact at CPSC →

2019

CPSC 20009Ductless heat pump

Carrier Recalls Carrier- and Bryant-Branded Heat Pumps Due to Fire Hazard

Hazard
The fan motor on the heat pumps can fail, causing the units to overheat, posing a fire hazard.
Remedy
Consumers should immediately contact their installing servicer, dealer or contractor to arrange for a free repair. While awaiting repair, consumers should monitor affected units while they are being operated and keep foliage and other flammable items at least 24 inches away from the recalled units.
Units
About 5,350 (in addition, about 450 were sold in Canada)
Models, serial ranges and contact at CPSC →

2018

CPSC 18115Air handler / blower

Goodman Manufacturing Recalls Modular Blowers Due to Fire Hazard

Hazard
The labels found on the serial plate have incorrect electrical information that could result in installers and servicers using undersized wiring or incorrect fuse/circuit breaker parts, posing a fire hazard.
Remedy
Consumers should immediately stop using the recalled modular blowers and contact Goodman for a free inspection and to receive a new product label and electrical instructions. For any units that were installed incorrectly, Goodman will replace the wiring and/or fuse/circuit breaker protection at no cost to the consumer.
Units
About 1,650 in the U.S. (In addition, about 80 were sold in Canada)
Models, serial ranges and contact at CPSC →

2017

CPSC 17150Heat pump

Carrier and Bryant Recall Heat Pumps Due to Fire Hazard

Hazard
The capacitors in the fuse boards in the heat pumps can stop working causing the unit to overheat, posing a fire hazard.
Remedy
Consumers should contact Carrier or Bryant for instructions on receiving a free replacement fuse board installed by authorized Carrier or Bryant technicians.
Units
About 23,300 (In addition about 2,000 sold in Canada)
Models, serial ranges and contact at CPSC →
CPSC 17145Gas furnace

Goodman Recalls Furnaces Due to Electrical Shock Hazard

Hazard
The blower motor is not grounded, posing an electrical shock hazard to individuals servicing the units
Remedy
Consumers should immediately contact Goodman for a free repair.
Units
About 4,100
Models, serial ranges and contact at CPSC →
CPSC 17103Air handler / blower

Goodman Recalls Air Handlers Due to Electrical Shock Hazard

Hazard
The pull-out disconnects may not disable power to the air handler, posing an electrical shock hazard to individuals servicing the units.
Remedy
Consumers should immediately contact Goodman for a free inspection and free repair. Goodman is contacting all known commercial owners directly.
Units
About 210,000 (in addition, 20 were sold in Canada)
Models, serial ranges and contact at CPSC →

2016

CPSC 17709Gas furnace

Trane Recalls Furnaces Due to Shock Hazard (Recall Alert)

Hazard
The ground wire in the furnace's junction box can become loose. If an electrical component then fails and short circuits, the unit poses a shock hazard.
Remedy
Consumers should contact Trane to receive a free replacement junction box and free installation. The firm is contacting customers directly. Consumers should avoid contact with the furnaces until the junction box is replaced.
Units
About 17,700
Models, serial ranges and contact at CPSC →

2015

CPSC 15746Air handler / blower

Trane and American Standard Recall Accessory Heaters Due to Fire Hazard (Recall Alert)

Hazard
Heaters installed with reverse polarity on one of the breakers can cause the heater to overheat, posing a fire hazard.
Remedy
Consumers should immediately stop using the heater function by switching the system to cooling mode or off, and contact their Trane or American Standard independent dealer to schedule an inspection and replacement. The system's air conditioning or cooling function may still be used. Trane is contacting its customers directly.
Units
About 3,900
Models, serial ranges and contact at CPSC →

2014

CPSC 14737Outdoor unit

Trane Recalls Air Conditioning Systems Due to Shock Hazard (Recall Alert)

Hazard
The ground screws used in some units do not have the two threads required to provide sufficient grounding, posing a shock hazard to consumers.
Remedy
Consumers should immediately turn off the cooling unit via the main breaker switch and check the model information. Consumers with recalled air conditioning systems should contact Trane or their installer or service dealer for instructions on scheduling a free inspection and repair.
Units
About 100,600
Models, serial ranges and contact at CPSC →

2013

CPSC 13715Packaged unit

Goodman Company Recalls Amana Heating and Cooling Units Due to Fire Hazard

Hazard
The serial plates on the units have inaccurate information that could result in installers and servicers using undersized wiring, posing a fire hazard.
Remedy
Consumers should contact Goodman for a free replacement of the serial plate label and a free inspection of the installation wiring. Goodman is directly contacting customers who purchased the recalled units.
Units
About 155
Models, serial ranges and contact at CPSC →

2012

CPSC 12102Gas furnace

Fire Concerns Prompt York International to Reannounce Recall of Gas Furnaces for Manufactured Homes

Hazard
The furnace can overheat and cause the heat-exchanger to crack and create openings that allow flames to be exposed. When this happens, drywall and other nearby combustibles are exposed to the flames, posing a fire and smoke hazard to consumers.
Remedy
Consumers should immediately stop using the furnace until it has been inspected and repaired. Consumers should contact UPG to schedule a free inspection and repair of any furnace involved in the recall.
Units
About 223,600 in the U.S. and 2,400 in Canada (previously recalled in November 2004)
Models, serial ranges and contact at CPSC →

What is and is not on this page

Included: split and ductless heat pumps, outdoor units, packaged units, air handlers and blowers, indoor coils, and gas furnaces. Left out: hotel-style PTAC and through-the-wall units, window and portable air conditioners, commercial rooftop units and thermostats — CPSC has recalls for all of those too.

CPSC’s search does not catch everything by keyword, so this list was built by cross-checking many queries and is reviewed by hand. If you know of a residential HVAC recall that is missing, the members’ forummembers’ forum is the place to tell us.

Sources

Federal rules change. This page reports what the sources said on the date above; the source is the authority, and state or local rules can be stricter. It is reference material, not legal advice and not installation guidance.